PE5000 - PE5100 - PE5200

PE5000 - PE5100 - PE5200

€425.80
Tax excluded

PRICE PER PIECE

Detection
Quantity

 

 

 

The peristaltic pumps that we propose are of three different types: PE5000, PE5100, PE5200:

PE5000

The PE5000 is driven by a compressor signal from the air 

conditioner. It stops 3 minutes after the compressor stops.

This pump must NOT be used:

- with Inverter type air conditioners;

- with continuous operation.

KIT CONTENT:

peristaltic pump PE 5000;

cable: 1,7 m (5,57 ft), 2 wires for power supply (phase and neutral), 1 wire for compressor signal;

sliding plastic plate, easy to mount (1 fixing screw);

adapter PE5003 to reduce the diameter from 15mm to 6mm (0,59"-0,23") + rubber Ø 15 x 35mm (Ø0,59"x1,37").

MAIN FEATURES

Reduced maintenance costs thanks to the replaceable head and the easily accessible tube

Low sound level

Given its IP65 protection, no ventilation is required

PE5100

The PE5100 is controlled by 2 thermal probes. As soon as the 

temperature difference reaches 6°C (42,8F), the pump starts

operating. It stops 3 minutes after the temperature difference

has returned below 6°C (42,8F).

This pump must NOT operate continuously.

KIT CONTENT:

peristaltic pump PE 5100;

cable: 1.7 m (5,57ft), including 2 wires for power supply (phase and neutral);

2 thermal probes with 3.5m (11,48 ft) cable : Red terminal for ambient air ; Blue terminal for cold air;

sliding plastic plate, easy to mount (1 fixing screw);

adapter PE5003 for diameter reduction from 15 mm to 6 mm (0,59"-0,23") + rubber Ø 15 x 35mm (Ø0,59"x1,37").

MAIN FEATURES

Reduced maintenance costs thanks to the replaceable head and the easily accessible tube

Low sound level

Given its IP65 protection, no ventilation is required

PE5200

The PE5200 is operated via a 3-level float detection block (run/stop/safety contact).

The alarm contact is normally closed and allows the air conditioning compressor or a solenoid valve to stop automatically when the safety level is reached.

KIT CONTENT:

peristaltic pump PE 5200;

cable: 1,7 m (5,57 ft), including 2 wires for power supply (P &N);

2 safety switch wires (1,7 m/5,57 ft);

easy “1 screw” sliding plastic bracket;

detection unit (SI2958, 1.5m/4,92 ft cable);

detection unit installation kit: pale rubber Ø 15mm x 35mm (Ø0,59"x1,37"); vent tube int Ø 4mmxL75 mm (Ø0,15"x2,95"); mounting rail; adhesive.

MAIN FEATURES

Reduced maintenance costs thanks to the replaceable head and the easily accessible tube

Low sound level

Given its IP65 protection, no ventilation is required

PE5000
500 Items

Download

PE-5000 IT SCHEDA TECNICA

Download (127.62k)

PE-5000 EN DATA SHEET

Download (340.08k)

PE-5100 IT SCHEDA TECNICA

Download (113.59k)

PE-5100 EN DATA SHEET

Download (266.46k)

PE-5200 IT SCHEDA TECNICA

Download (117.87k)

PE-5200 EN DATA SHEET

Download (304.89k)

You might also like